Japanese Government Procurement
National University Corporation - Notice of request for submission of materials1 set of Nuclear Magnetic Resonance (NMR) System
This procurement is covered by the WTO Agreement on Government Procurement, Japan-EU Economic Partnership Agreement or Japan-UK Comprehensive Economic Partnership Agreement.
Publishing date | Sep 11, 2023 |
---|---|
Type of notice | Notice of request for submission of materials |
Procurement entity | National University Corporation - Shimane |
Classification |
0024 Professional/Scientific & Controlling Instruments & Apparatus |
Summay of notice | ⑴ Classification of the products to be procured : 24 ⑵ Nature and quantity of the products to be purchased : 1 set of Nuclear Magnetic Resonance (NMR) System ⑶ Type of the procurement : Purchace ⑷ Basic requirements of the procurement : A The superconducting magnet (SCM) of the NMR system must generate a magnetic field of 11.74 Tesla (corresponding to 500MHz) and be capable of being transported and carried with liquid cryogen (liquid helium and nitrogen) in it. B The minimum retention period for liquid helium and nitrogen in the SCM must be 150 days and 15 days, respectively. The SCM must be equipped with a cryogen reclamation system to control evaporated cryogen for both helium and nitrogen. C The frequency band of the NMR spectrometer must be 460-535 MHz for the high frequency (HF), and 10-210 MHz for low frequency (LF). D The temperature variable range in the NMR spectrometer must be between -170 ℃ to 250 ℃, and compressed air must be available for NMR measurements above 80 ℃. E The spectrometer must be available for both solid and liquid samples. F The NMR detector for liquids must have a diameter of 5 mm and be capable of detecting nuclei of 1H, 19F, 15N-31P, 39K, and 109Ag. G The NMR detector for solids must have a diameter of 3.2 mm and be capable of detecting nuclei of 1H, 19F, 31P, 7Li, 11B, 23Na, 27Al, 13C, 79Br, 207Pb, 29Si, 6Li, and 15N. H The system must be equipped with an automatic sample changer with at least 24 slots, which must be available for both solid and liquid NMR measurements. I The system must have a second workstation for remote control and operation of the system. ⑸ Time limit for the submission of the requested material : 17 : 00 13 October, 2023 ⑹ Contact point for the notice : NISHIMURA Shuhei, Accounts Division, Finance Department, The National University Corporation Shimane University, 1060 Nishikawatsu-cho Matsue-shi 690-8504 Japan, TEL 0852-32-6027 |