Japanese Government Procurement
National University Corporation - Notice of request for submission of materialsEnhanced Operation System 1 Set
This procurement is covered by the WTO Agreement on Government Procurement, Japan-EU Economic Partnership Agreement or Japan-UK Comprehensive Economic Partnership Agreement.
Publishing date | Aug 08, 2022 |
---|---|
Type of notice | Notice of request for submission of materials |
Procurement entity | National University Corporation - Ishikawa |
Classification |
0022 Medical/Dental/Surgical & Veterinary Equipment
0031 Medical Instruments & Apparatus |
Summay of notice | ⑴ Classification of the products to be procured : 22, 31 ⑵ Nature and quantity of the products to be purchased : Enhanced Operation System 1 Set ⑶ Type of the procurement : Purchase ⑷ Basic requirements of the procurement : 1)MR-OR System ① The magnet type shall be superconducting and the operating static field strength shall be 3.0T. ② The diameter of the center of the gantry bore shall be of the large diameter type. ③ The system shall have a mechanism that does not consume liquefied helium during normal inspection. ④ Maximum gradient field strength output shall be possible in each of the three axes. ⑤ Maximum slew rate output shall be possible in each of the three axes. ⑥ The patient's bed shall be able to cooperate surgery patient's bed. ⑦ The RF coil shall be compatible with imaging during surgery. 2)Hybrid-OR system ① The biplane imaging system should have two sets of X-ray tube and detector pairs. ② Have reduce exposure system for staffs and a patient. ③ It can be connected with beds. ④ It must be able to connect to existing hospital information systems (HIS), radiological information systems (RIS), image interpretation systems, and image networks (PACS). ⑤ Have a large monitor. ⑥ It should be equipped with a workstation enables image processing. 3)Surgical Image Management System ① It must be a centralized system that have images of operating field at each operating room, images during surgery and biological informations etc. ② It is necessary to connect existing surgical image management system. ③ It must be taken by 4K high image quality (3840×2160) on the operating field, also control camera at each surgery and operating field by moving lengthwise, sidewise, rotation and zoom in. ④ To provide a camera having a medical monitoring device whose image quality is 4K high (3840×2160). ⑤ Recording of surgical field footage in all operating rooms can be stored in high definition for one year and compressed low-resolution recordings that can be stored for 5 years. Recorded footage must be searchable by date, patient ID, clinical department, etc. ⑥ It is possible to record surgical cameras, images and images of each medical device using a touch panel with simple operation, and to be able to store them for a long time on a server system. ⑦ All operating room operative field (panoramic view) cameras and recorded surgical field images can be viewed in multiple locations. ⑧ Two-way communication of images, video and audio is possible with the pathology diagnosis department during surgery. 4)Ultrasound diagnostic imaging system ① Ultrasound diagnostic imaging system A 1-1 It must be compatible with real-time 3D transesophageal echocardiography. ② Ultrasound diagnostic imaging system B 2-1 Portable ultrasound diagnostic imaging system for transesophageal echocardiography. ③ Ultrasound diagnostic imaging system C 3-1 Perioperative management central venipuncture must be supported. ④ Ultrasound diagnostic imaging system D 4-1 Ultrasound diagnostic imaging system compatible with surgical robot. 5)Mobile C-arm system ① Mobile C-arm system 1-1 It must be type of C-arm system. 1-2 Have a digital photography. 1-3 Equipment for reducing radiation exposure. 1-4 It must be able to connect to existing hospital information systems (HIS), radiological information systems (RIS), image interpretation systems, and image networks (PACS). ② Mobile X-ray system with DSA 2-1 It must be type of C-arm system. 2-2 Have a digital photography. 2-3 Equipment for reducing radiation exposure. 2-4 It must be able to connect to existing hospital information systems (HIS), radiological information systems (RIS), image interpretation systems, and image networks (PACS). 2-5 Have a Digital subtraction angiography function. 6)Mobile radiography ① It should have a pantograph arm to easily control the position of photograph. ② Small-size and small-turn. 7)Patient transport system ① Patients can enter and leave the room safely and smoothly. ② It should be possible to easily enter and leave the operating table or table top for the operating table according to the surgical procedure. ③ The operating table should be compatible with a wide variety of surgical procedures. ④ Compatible with existing operating table accessories owned by the operating department. 8)Surgical light/sealing pendant anchoring system ① The surgical light should be a surgical lighting that is suspended from the ceiling and allows the light field to reach deep into the surgical field. ② The surgical light should be dual-axis and dual-light. ③ Surgical light should be a system on which a monitor for a video system can be suspended. ④ The sealing pendant is a ceiling-mounted type that takes into consideration the flow lines of staff and objects, care space, and efficiency of treatment and care. Layout is possible. ⑤ The sealing pendant is able to supply a medical gas and a power source etc. 9)Acute patient information system ① Recordable anesthesia records, patient vital data, and medication information during surgery. ② Being able to automatically acquire and record data from biological information monitors and anesthesia machines. ③ It must be able to connect to existing hospital information systems (HIS). 10)Anesthesia System ① Have an automatic ventilation mode for all patients from neonatal to adults. ② General anesthesia using the exhaled gas rebreathing system. ③ Being able to output data from the anesthesia system to the acute care patient system. 11)Biological information monitoring system ① Being able to continuously monitor the patient's biological information during surgery. ② Being able to measure cardiogram/respiration, noninvasive blood pressure, SpO2 and plural parameter. ③ The monitor and the display are integrated. 12)Automatic Storage System ① Enables speedy storage of & access to a variety of containers of instruments sets. ② More than 350 containers can be stored in a small space. 13)Blood purification system ① The device must be capable of producing water suitable for hemodialysis. ② Being able to perform hemodialysis treatment. ③ Being able to perform acute blood purification therapy. 14)Surgical support system ① Blood gas analysis, electrolytes, metabolism, and hemoglobin can be measured by actual measurement for patient monitoring during surgery. ② Capable of showing percent and real number for leukocyte classification. ③ Easy operation to be able to measure rSO2 immediately even in an emergency ④ Optimal anticoagulation with heparin during extracorporeal circulation, and perform safe extracorporeal circulation. ⑤ Provides a comprehensive view of hemodynamics. ⑥ Surgery that is efficient and less invasive, and reduces bleeding by incision, evaporation, hemostasis, and cauterization using monopolar and bipolar high-frequency currents can be performed quickly and safely. 15)Surgical hand washing system ① A system that can disinfect hands and fingers for the purpose of removing passing bacteria adhering to the fingers and reducing resident skin bacteria. ② In order not to be affected by deterioration of raw water quality, a filter or membrane should be built into each hand washer. ③ The faucet should be able to prevent reverse pollution. 16)Ophthalmic Surgical Microscope System ① Enable speedy storage of & access to a variety of containers of instruments sets (specific to procedures) ② Microscope images can be displayed on external monitor and connected to recording system. ③ Accommodates surgery of the retina and/or vitreous body as well as cataract surgery. ⑸ Time limit for the submission of the requested material : 17 : 00 30 September, 2022 ⑹ Contact point for the notice : Yasuhiko Nakamura, Procurement management Section, Hospital Management Division, Hospital Department, Kanazawa University, 13-1 Takara-machi Kanazawa-shi 920-8641 Japan, TEL 076-265-2067 |