Japanese Government Procurement
National University Corporation - Notice of request for submission of materialsBiochemistry and immunological testing system 1 Set
This procurement is covered by the WTO Agreement on Government Procurement, Japan-EU Economic Partnership Agreement or Japan-UK Comprehensive Economic Partnership Agreement.
| Publishing date | Dec 11, 2023 |
|---|---|
| Type of notice | Notice of request for submission of materials |
| Procurement entity | National University Corporation - Miyazaki |
| Classification |
0022 Medical/Dental/Surgical & Veterinary Equipment
0031 Medical Instruments & Apparatus |
| Summay of notice | ⑴ Classification of the products to be procured : 22, 31 ⑵ Nature and quantity of the products to be purchased : Biochemistry and immunological testing system 1 Set ⑶ Type of the procurement : Purchase ⑷ Basic requirements of the procurement : A Biochemistry analyzer-one unit ⒜ Must be capable of performing simultaneous multi-item analysis using a discrete method. ⒝ The instrument should process a maximum of 5,400 tests per hour for the photometric method and maximum of 1,800 tests per hour for the electrolytic method. B Specimen Pretreatment Conveyance System-one unit ⒜ Must be able to connect to multiple biochemical autoanalyzers and immunochemiluminescence analyzers. ⒝ The system should be capable of processing more than 500 specimens per hour at a 1 : 1 dispensing ratio. ⒞ The dispensing area should be able to detect liquid levels. ⒟ It should be able to dispense 200-800 〓 at once. ⒠ The dispensing area of the system should have droplet prevention function. ⒡ The system can store more than 400 processed specimens. ⒢ It should be able to replenish consumables even during operation. ⒣ It should be selectable of the right/left direction where the specimens are conveyed to. ⒤ It should have a backup device. C Immunoassay system-one unit ⒜ The system should have a processing capability of 200 tests per hour. ⒝ Sample capacity should be more than 150 samples. ⒞ It should have an automatic re-examination function. ⒟ IT should have a backup device with equal performance to the main unit. D Seismic isolator device-one unit ⒜ The device should be installed with seismic isolation. ⒝ The height of the seismic isolator should be less than 10 mm. ⒞ It should withstand a superimposed load of more than 500 kg per square meter. ⒟ It does not need regular maintenance. E Temperature Control System-one unit ⒜ It can use cloud servers. ⒝ The operational status of the equipment can be checked in real time. ⒞ Data should be downloadable in CSV format. F Benchtop Centrifuge-one unit ⒜ Maximum rotation per minute should be more than 3,500 rpm. The maximum centrifugal force should be more than 2,300×g. G Floor-Standing Refrigerated Centrifuge-one set ⒜ Maximum rotation per minute should be more than 4,800 rpm. The maximum centrifugal force should be more than 4,150×g. ⑸ Time limit for the submission of the requested material : 17 : 00 26 January, 2024 ⑹ Contact point for the notice : Takanori Kurogi, Procurement Section, Accounting Division, National University Corporation University of Miyazaki, 1-1 Gakuen Kibana-dai Nishi Miyazaki-shi 889-2192 Japan, TEL 0985-58-7574 |


