Japanese Government Procurement
Ministry of Defense - Notice of request for submission of materialsComplete blood coagulation urine general test analysis system 1 Set
This procurement is covered by the WTO Agreement on Government Procurement, Japan-EU Economic Partnership Agreement or Japan-UK Comprehensive Economic Partnership Agreement.
| Publishing date | Feb 20, 2023 |
|---|---|
| Type of notice | Notice of request for submission of materials |
| Procurement entity | Ministry of Defense - Saitama |
| Classification |
0022 Medical/Dental/Surgical & Veterinary Equipment
0031 Medical Instruments & Apparatus |
| Summay of notice | ⑴ Classification of the products to be procured : 22, 31 ⑵ Nature and quantity of the products to be purchased : Complete blood coagulation urine general test analysis system 1 Set ⑶ Type of the Procurement : lease ⑷ Time limit for the submission of the requested material : 17 : 00 7, April, 2023 ⑸ Basic requirements of the Procurement ① System configuration : (A) Automated hematology system 1 Set (A)-1 Hematology analyzer (A)-2 Automatic smear preparation equipment (A)-3 Automatic Blood Images Analyzer (A)-4 Specimen Sorter (A)-5 Blood Test Delivery Line (B) Hematology analyzer 1 Set (C) Hematology analyzer (small instrument) 1 Set (D) Fully Automated Urine Particle Analyzer 1 Set (E) One fully automated blood coagulation machine 1 Set ② System performance : (A) Automated hematology system 1 Set The blood test conveyance line system shall be capable of performing a series of processes automatically by connecting four hematology analyzers, one automatic smear preparation device, one automatic blood image analysis device and one sample rearrangement device with the following functions on the conveyance line. (A)-1 Hematology analyzer ① Blood cell count, white blood cell differential and reticulocyte measurement systems can be measured by laser light or electrical resistance. ② 8 items of blood count (White blood cell count, red blood cell count, hemoglobin concentration, hematocrit value, platelet count, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration), white blood cells differential (Neutrophils, eosinophils, basophils, lymphocytes, monocytes) and reticulocytes can be measured. ③ In the measurement of platelets, it should have a fluorescent staining measurement mode and be able to measure platelets with high accuracy and precision. ④ It should have a dedicated mode for measuring body fluids. ⑤ Processing capacity should be at least 110 samples per hour for blood count and white blood cell differential, and at least 80 samples per hour for blood count, white blood cell differential, and reticulocyte. ⑥ It should have automatic and manual modes when sampling during specimen measurement. ⑦ It can be measured with a sample aspiration volume of 90 μl or less in whole blood measurement mode. (A)-2 Automatic smear preparation equipment ① Smear preparation should be wedge method. ② It should be stained by the Meigrinwald-Giemsa staining method and should be able to stain automatically. ③ The staining process and time can be set. ④ Processing capacity should be at least 75 samples per hour. ⑤ It can be measured with a sample aspiration volume of 70 μl or less in normal measurement mode. ⑥ It should be able to stain manually prepared smears at the same time. ⑦ It should be able to print necessary information (barcodes, alphanumeric characters) on the frosted part of a slide glass. (A)-3 Automatic Blood Images Analyzer ① It should automatically be able to classify band neutrophils, segmented neutrophils, eosinophils, basophils, lymphocytes, monocytes, promyelocytes, myelocytes, metamyelocytes, blasts, atypical lymphocytes and plasma cells by digital image analysis of smears. ② It should be able to characterize polychromatic cells, hypochromatic cells, anisocytosis, microcytes, macrocytes and poikilocytosis. ③ Maximum Processing capacity of peripheral blood samples should be at least 30 samples per hour. ④ It should be able to read the one- and two- dimensional barcodes printed on the specimen with an Automatic smear preparation equipment and receive patient information from laboratory information system. ⑤ It should be able to display the blood count result and white blood cell differential result of the automatic blood cell counter when viewing the measurement result as requested information from laboratory information system. ⑥ With network connection, work such as viewing measurement results and approving specimens can be performed at a PC terminal far from the equipment. (A)-4 Specimen Sorter ① It should be able to sort samples automatically. ② It should be able to store at least 1000 specimens at a time. ③ It should be able to sort samples according to their intended use, such as for normal samples and retesting. ④ Separation of storage areas should have a function that can be set for each user. (A)-5 Blood Test Delivery Line ① The specimen feeder should have a function corresponding to 10 column specimen racks on which a 2 ml blood collection tube can be carried. ② It should be equipped with a barcode reader that automatically confirms arrival. ③ It should be able to warn of barcode reading errors. (B) Hematology analyzer 1 Set ① It should be of the same manufacturer as the (A)-1Hematology analyzers. ② It should have the same functions as (A)-1. (C) Hematology analyzer (small instrument) 1Set ① It can be installed in a clean bench in a controlled laboratory in our hospital. ② It should be of the same manufacturer as the (A)-1Hematology analyzers. ③ 8 items of blood count (White blood cell count, red blood cell count, hemoglobin concentration, hematocrit value, platelet count, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration) and white blood cells differential (Neutrophils, eosinophils, basophils, lymphocytes, monocytes) can be measured. ④ It can be measured with a sample aspiration volume of 25 μl or less in whole blood measurement mode. (D) Fully Automated Urine Particle Analyzer 1 Set ① It should have a carrier line that can be connected to this Fully Automated Urine Particle Analyzer, our hospital's fully automatic urine collection system to be procured separately, and fully automatic urine qualitative testing system. ② Specimens should be collected from raw urine and no prior treatment such as centrifugation is required. ③ The measurement principle should be flow cytometry with a blue semiconductor laser ④ The measurement results should be converted from/μl and/μl to/LPF, /HPF, etc. based on quantitative measurements. ⑤ 6 items of red blood cells, white blood cells, epithelial cells, squamous epithelial cells, casts, and bacteria can be quantitatively measured, and 8 items of leukocyte aggregation, non-squamous epithelial cells, hyaline casts, nonhyaline casts, crystals, yeast-like fungi, sperm, and mucous threads can be semiquantitatively or qualitatively measured. ⑥ Processing capacity should be at least 100 samples per hour. ⑦ The required sample volume should be at most 2.0ml and the sample aspiration volume should be at most 0.5ml. (E) One fully automated blood coagulation machine 1 Set ① PT, APTT, Fbg, AT, FDP, D-dimer, TPAI/C, TAT and PIC can be measured on one device. ② The detection method of the coagulation method should be a transmission light detection method. ③ Processing capacity should be at least 450 tests per hour for PT. ④ It should have 5 or more wavelengths used for measurement. ⑤ The sampling method of a specimen should have a cap-piercing function. ⑥ It should have a rack sampler. ⑦ At least 120 specimens can be stored. ⑧ It should have an automatic retesting function. ③ Others (A) It should be highly safe and easy to be operated. (B) It should be able to be upgraded in the future. ⑹ Contact point for the notice : Makoto Komachi, General Affairs and Planning, Administrative Department, National Defense Medical College Hospital, 3-2 Namiki Tokorozawashi Saitama 359-8513 Japan TEL 04-2995-1511 (ext. 3017) |

